“10 IU / 3.3 mg” states one labelled amount in two units: international units (IU) and milligrams (mg). The WHO International Standard for somatropin defines 3.0 IU per milligram, so 10 IU divided by 3 gives 3.33 mg, which the label rounds to 3.3 mg. Neither figure is a measurement of a particular vial. Measured amounts come from a laboratory report on a tested sample.
International units vs milligrams: two ways to state an amount
A milligram is a unit of mass. For somatropin, the international unit is tied to a reference material instead: the WHO International Standard for Somatropin, NIBSC code 98/574. Its instructions describe it as intended for calibrating potency assays for somatropin preparations and immunoassays for human growth hormone.
The current standard was established by the WHO Expert Committee on Biological Standardization in 2001. It replaced the first International Standard, coded 88/624. The instructions explain that 98/574 is value-assigned in mass units, so that somatropin content can be assigned in milligrams, for example by HPLC. They add that the mass value “can be converted to the historical International Unit (IU) if desired.”
In other words, the milligram is the primary unit for the current standard, and the IU figure on a label is a conversion from it. For background on the protein itself, see what somatropin is.
The WHO standard behind 3 IU per mg
The unitage section of the 98/574 instructions states two values:
- “1.95 mg per ampoule (total somatropin protein, including higher molecular weight forms and related impurities)”; and
- “3.0 International units per mg Somatropin”.
The instructions note that the international unit of 98/574 “is assigned without uncertainty”. They also note that the 3.0 IU per mg figure relates to somatropin monomer, which laboratories should determine independently.
These values came from an international collaborative study involving 16 laboratories in nine countries. The study report, published in Biologicals in 2001, records that WHO agreed “the specific activity of the preparation should be defined as 3.0 IU/mg somatropin.”
The same convention appears in regulatory labelling. The FDA prescribing information for Nutropin, an approved somatropin product, describes a 10 mg vial as containing “10 mg (approximately 30 IU) somatropin”. A footnote in the same document reads: “Based on current International Standard of 3 IU = 1 mg”.
Converting IU to mg: why 10 IU ≈ 3.3 mg
At 3.0 IU per mg, the arithmetic is simple. To go from IU to mg, divide by 3. To go from mg to IU, multiply by 3.
| International units | Milligrams |
|---|---|
| 3 IU | 1 mg |
| 10 IU | 3.33 mg (shown on the label as 3.3 mg) |
| 36 IU | 12 mg |
Because 3.3 mg is rounded, converting it back gives 9.9 IU rather than exactly 10 IU. The two figures on the label describe the same amount within rounding; they are not two separate results.
The Synatropin kit label text reads “10 Vials × 10IU / 3.3mg”. That line gives the labelled amount per vial and the number of vials in the kit. Our guide to vials and kits compares the single vial, the 10-vial kit and the 20-vial set.
Why a lab report can state a measured IU figure
Both reports on the Synatropin lab-report page name an HPLC method. As noted above, the WHO standard is value-assigned in mass so that somatropin content can be assigned in milligrams, for example by HPLC. A laboratory that wants to report in IU can convert a measured mass using 3 IU per mg. Our HPLC explainer covers how chromatography results are reported.
The 36 IU report shows this directly. It is a Testides report, LK-HGH-36-021126, tested on 23 February 2026 by HPLC-UV, with Cellugenix listed as the client. It reports:
- purity: 99.29%;
- total content: 39.83 IU;
- expected content: 36 IU; and
- fill accuracy: 110.6%.
Fill accuracy is the measured content divided by the expected content: 39.83 ÷ 36 is about 110.6%. The notes section reads “Assumed bioreactivity 3IU to 1mg.” and “13.27mg”. At 3 IU per mg, 39.83 IU corresponds to roughly 13.3 mg, in line with the figure in the notes.
The word “assumed” matters. The report names HPLC-UV as its method and does not list a separate test of biological activity. Its IU figure applies the 3 IU per mg convention to a chromatographic result. A biological potency test is a different kind of measurement; the Nutropin label, for example, states that its potency “is determined using a cell proliferation bioassay.”
The 10 IU report is a Lingda Laboratory report, YLBP20261282, issued on 6 October 2026, with yonglibiopeptide.com listed as the client. It reports chromatographic purity of >99.18% ± 0.18% and a quantity of 10.04 IU, both by HPLC-UV/VIS. It does not print a conversion factor or a milligram figure. If a report does not say how it moved between mass and IU, that is a reasonable question to ask.
A measured amount applies to the sample tested
A quantity on a laboratory report describes the sample that laboratory received. The Lingda report says so in its own disclaimer: “This report relates only to the sample(s) tested.” A result of 39.83 IU or 10.04 IU is not a statement about every vial in a kit, or about vials from a different production run.
Keep these points in mind when comparing the two reports:
- The 36 IU report describes a sample with 36 IU expected content. It is not a test of a 10 IU vial.
- Neither report names Synatropin as its client.
- Neither report lists a lot number. The kit labels show LOT#7.09.25-1.
Contact Synatropin to confirm which report applies to your order. Our guide on how to read a COA explains how to match identifiers, sample details and results.
Labels, reports and product listings
Review the available Certificates of Analysis for the full documents, and the glossary for terms used on labels and reports. Current pricing is on the shop page.
Products are for laboratory research use only, not for human or animal use. This article explains how amounts are stated on labels and reports; it does not provide preparation, dosing or administration instructions.
