HPLC purity on a Certificate of Analysis compares the area of the main peak with the total area of the peaks the laboratory measured, expressed as a percentage. It describes how one tested sample separated under one method. On its own it does not confirm identity, quantity or sterility.
What is high-performance liquid chromatography?
Chromatography separates a mixture into its components. A mobile phase carries the sample over a stationary phase, and the components separate because each one interacts differently with the two phases, as the NCBI Bookshelf overview of chromatography explains. In high-performance liquid chromatography (HPLC), the solvent is pushed through a packed column under high pressure, which allows closely related compounds to be separated in a few minutes. A detector at the end of the column records the signal as each component comes out.
The same overview notes that, in pharmacology, chromatography is used to estimate the purity and potency of drugs. That is the role HPLC plays on a COA: it is a separation method with a detector attached, and the report is a record of what that detector saw for one sample.
What does a chromatogram show?
A chromatogram is the detector’s printout. According to the NCBI overview, the horizontal axis shows time, the vertical axis shows signal intensity, and each peak represents a compound leaving the column. Three terms do most of the work:
- Retention time is the interval between injection and the top of a peak. Under fixed conditions, a compound has a characteristic retention time.
- Peak area is the area under a peak, which represents the quantity of that compound eluted.
- Baseline is the background signal between peaks, which helps show the noise level.
On the Synatropin 10 IU report from Lingda Laboratory (report YLBP20261282), the largest peak appears at 9.913 minutes and is labelled “HGH”, with an area of 4591.49. A much smaller peak appears just before it, at 9.661 minutes, with an area of 20.2048. The header records the detector channel and signal setting (“DAD1 A, Sig=214,4 Ref=off”) and a run date of 3 October 2026.
How is chromatographic purity calculated?
The FDA’s edition of the ICH Q2(R2) guideline on validating analytical procedures treats purity expressed “as area %” as one of the kinds of result an analytical procedure can report. Area-percent purity divides the main peak’s area by the combined area of all integrated peaks. The NCBI overview notes that peak areas tend to give a more precise measurement than peak heights.
The report does not include a peak table, so it does not show which peaks were integrated or exactly how its figure was calculated. Quote the laboratory’s stated result, >99.18% ± 0.18%, rather than a figure estimated from the chromatogram image.
| Item | As printed on the report |
|---|---|
| Method | HPLC-UV/VIS |
| Main peak | 9.913 min, labelled “HGH”, area 4591.49 |
| Smaller labelled peak | 9.661 min, area 20.2048 |
| Chromatographic purity | >99.18% ± 0.18% |
| Quantity | 10.04 IU |
| Purity specification | Not printed beside the result |
What does UV detection mean, and why does the method matter?
“UV/VIS” refers to an ultraviolet–visible absorbance detector. The NCBI overview lists ultraviolet detectors among the most commonly used in clinical laboratories. As the Chemguide introduction to HPLC describes, a beam of UV light passes through the liquid leaving the column, and the detector reads how much light is absorbed.
That has a practical consequence. Chemguide notes that peak area is proportional to the amount of a compound passing the detector, but that a smaller peak could equally reflect a compound that absorbs less light at the wavelength being used. An area-percent figure therefore reflects how strongly each component absorbs, not only how much of it is present. Two components that leave the column together can also appear as one peak. ICH Q2(R2) says that, for critical separations, specificity can be shown by the resolution of the two components that elute closest to each other. Where one procedure does not discriminate well enough, the guideline recommends combining two or more procedures.
For the same reasons, a purity figure only means something alongside the method that produced it. Chemguide notes that retention time varies with pressure, the stationary phase, the solvent composition and the column temperature. The NCBI overview adds that a pH change of 0.1 units can shift retention time by as much as 10% for ionizable samples. The separate 36 IU report from Testides (LK-HGH-36-021126) lists its method as HPLC-UV and its purity as 99.29%, with no ± figure, and a total content of 39.83 IU against 36 IU expected. Because the two reports come from different laboratories, describe their methods differently and tested different samples, 99.29% and >99.18% ± 0.18% should not be compared as two readings from the same test.
What do the ± and > signs mean?
The greater-than sign means the report states that purity was above 99.18%, rather than giving one exact value. Keep the sign when quoting the result. Dropping it changes what the report says.
The ± 0.18% expresses a spread around the reported value. ICH Q2(R2) describes precision as the closeness of agreement between repeated measurements of the same sample, usually expressed as a variance, standard deviation or coefficient of variation. The 10 IU report does not say which measure its ± figure represents, how many measurements it is based on, or how the greater-than sign and the ± are meant to be read together. If that basis matters to your work, ask the laboratory.
The analytical results table lists the analysis, method and result, but no purity specification. The conclusion states that “the tested items meet the applicable specification requirements” without printing a purity acceptance limit next to the figure.
What HPLC purity does not tell you
- Identity on its own. The NCBI overview explains that a compound is identified by matching its retention time with a reference material run under the same conditions. ICH Q2(R2) describes identification tests as relying on unique aspects of the molecule’s structure or other specific properties. The report labels the main peak “HGH” but does not describe the reference material or any separate identity test.
- Quantity. Purity is a ratio. The 10 IU report lists quantity as a separate result, 10.04 IU, also by HPLC-UV/VIS. The guide to IU and mg labels explains how labelled amounts are expressed.
- Sterility, endotoxin or elemental impurities. These need different tests. The same report includes them in separate sections, covered in endotoxin, sterility and heavy-metal results on a COA.
- Other vials or lots. The report states that it “relates only to the sample(s) tested.” Neither currently posted report lists a lot number, and the kit labels show LOT#7.09.25-1.
Read the full reports
Open the original documents on the Certificates of Analysis page and read each result with its method, units and date. The guide to reading a COA covers identifiers and lot matching, and the glossary defines the terms used here. A report applies to the sample tested, so contact Synatropin to confirm which report applies to your order.